- INTRODUCTION The IR Thermometer is a non-contact,infrared tempera-ture measuring instrument that can be used in: HVAC, vehicle diagnostics, process control industry, food indus.
- Support User Manuals. Brand / Device. Product Types. Troubleshooting and Product Support. Kroger thermometer model no. 2010K manual. Kroger Thermometer 2017k. Correct usage. Kroger Thermometer 112-753-000. × Sign In to ManualsOnline.
- Infrared Thermometer Safety Information 3. Do not keep cells or batteries in a container where the terminals can be shorted. Do not put battery cells and battery packs near heat or fire. Do not put in sunlight. Caution To avoid damage to the Product or the equipment under.
- Infrared Thermometer Users Manual. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable. A Warning identifies conditions and procedures that are dangerous to the user.
1. Introduction
Non-Contact IR Thermometer User Manual Please read this manual before switching the unit on. Infrared Thermometer. This thermometer is. Temperature, etc. 2.Safety information' This device must only be used for the purposes described in this instruction manual' This device must only be used in an ambient temperature range between +10ºCto. General Tools & Instruments is the leader in specialty hand tools and precision instruments.
Congratulations on your purchase of the new IRT207
Heat Seeker
- We love this thermometer, but we almost returned it because changing the scales from Celsius to Fahrenheit is not intuitive, and the instruction manual is hi.
- Infrared Thermometer JPD-FR409 measures the body temperature based on the infrared energy emitted from the eardrum or the forehead. Users can quickly get measurement results after positioning properly the temperature probe in the ear canal or forehead. 2) Structure The thermometer consists of a shell, an LCD, a measure button, a beeper.
- Customer Review: Amplim Amp1701 Infrared Thermometer Video User Manual See full review. Amazon Influencer.
TM
Before using your body temperature measuring infrared thermometer, you need to read the instruction manual carefully to make sure you know all the specifications and functionality well. Being familiar with the specifications is very helpful for you to use your infrared thermometer more efficiently for checking more precise temperature reading.
InfraRed Thermometer (IRT). This IRT is
an 8:1 non-contact temperature measuring instrument
using infrared technology and laser sighting. Features
include a 4 digit backlit LCD, scan/hold function and
auto power off (7 secs). To measure a temperature,
point the unit at the object, pull the measuring trigger
and hold. Make sure the target area is larger than the
unit’s spot size.
2. Safety Information
CAUTION: Use of controls or adjustments or
performance of procedures other than those specified
herein may result in dangerous radiation exposure.
• DO NOT submerge the unit in water.
• This product is not designed for use in medical
evaluations. The product can only be used to
measure body temperature simply for reference.
The IRT is meant for industrial and commercial uses.
LASER WARNING NOTE!
Do not point laser directly at eye.
Use caution around reflective surfaces.
Keep out of reach of children.
This instrument conforms to the following standards:
EN61326: Electrical equipment for measurement, control
and laboratory use.
Cen Tech Infrared Thermometer Manual
IEC61000-4-2: Electrostatic discharge immunity test.
IEC61000-4-3: Radiated, radio-frequency,
electromagnetic field immunity test.
IEC61000-4-8: Power frequency magnetic field immunity
test.
Tests were conducted using a frequency range of
80-1000MHz with the instrument in three orientations.
The average error for the three orientations
is ±1.0ºF (±0.5ºC) at 3V/m throughout
the spectrum. However, between
781-1000MHz at 3V/m,
the instrument may not
meet its stated accuracy.
3. Specifications
4. Operation of Instrument
4-1 Quick Start
To measure a temperature, point the unit at the target you
want to measure, pull the trigger and hold. Move closer to
or farther from the target until it appears about the same
size as the laser’s circular measurement ‘spot’, which has
a D:S ratio (Field of View) of 8:1. The single spot of laser
is used for aiming purposes only.
The unit displays temperatures in either ºF or ºC.
Replace the battery when the battery voltage drops
below the voltage for reliable operation and the low
battery symbol
appears.
Temperature Range
-4º to 608ºF (-20º to 320ºC)
Accuracy
±2% of reading or 3.6°F (2°C),
whichever is greater
Field of View
8:1
Laser Type,
Class 2, <1mW @655nm
Output/Wavelength
Repeatability
±1ºC (±1.8ºF)
Response Time
500 ms.
Operation Temp. Hp m6 1045dx drivers.
32º to 104ºF (0º to 40ºC) @ 10 to 90% RH
Auto Power Off
Automatically after 7 sec.
Emissivity
Fixed at 0.95
Storage Temp.
14º to 122ºF (-10º to 50ºC)
ºF/ºC Switchable
YES
Backlight
YES
Laser Sight Switchable YES
Battery Type
“9V” battery (included)
Battery Life
16 hrs
Dimension
5.98 x 4.65 x 1.26 in. (152 x 118 x 32 mm)
Weight
4.22 oz. (120g) without battery
General Irt207 Infrared Thermometer Manual
Accessory
Infrared Thermometer Instruction Manual Pdf
“9V” battery, Instruction manual
5. Maintenance
Cleaning the lens: Blow off loose particles using clean
compressed air. Gently brush remaining debris away
with a camel’s hair brush. Carefully wipe the surface
with a moist cotton swab. The swab may be moistened
with water.
NOTE:
DO NOT use solvents to clean the glass lens.
Cleaning the housing:
Use soap and water on a damp sponge or soft cloth.
Battery Low
Temperature Display
SCAN
Yobekan Infrared Thermometer Instruction Manual
ºF/ºC Switch
Laser ON/OFF Indication
ºF/ºC Switch Indication
HOLD
Laser ON/OFF Switch
IRT207
Heat Seeker
TM
Pt Infrared Thermometer W89722 Manual
Infrared Thermometer
©2014 GENERAL TOOLS & INSTRUMENTS New York, NY 10013
Montreal, Canada H9R 1E1
Laser Certification Label
(on side of unit)
Ryobi Infrared Thermometer Manual
Berrcom JXB-178 User Guide
Intended use The device is an infrared thermometer intended to measure forehead temperature of infants and adults without contacting human body. It can be used by consumers in household environment and doctor in clinic as reference.
Introduction The JXB-178 Non-contact Infrared thermometer has been developed by using the latest infrared technology. This technology allows temporal artery (TA) temperature to be taken at a distance of about 3cm-5cm away from the forehead. Precise, Instantaneous and without Contact, the JXB-178 is, up to now, the most suitable thermometer for no risk on temperature measurement. It has been demonstrated that this method of TA temperature measurement is more precise than the tympanic thermometry and better tolerated than rectal thermometry
However, as with other types of thermometer, it is essential to use the JXB-178 properly in order to obtain reliable and stable results. You are therefore advised to read this instruction manual and the safety precautions carefully before use.
Greenes D, Fleisher G. Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants. Arch Pediatr Adolesc Med 2001;155:376.
Precautions before use
The JXB-178 is pre-set at the factory. It is not necessary to calibrate the device when starting it up.
In order to obtain reliable and stable results, you are advised each time there is a significant change in the ambient temperature due to a change in environment, to allow the JXB-178 to acclimatize to this ambient temperature for 15 to 20 minutes before using it. It is important to allow 3-5 seconds interval between two measurements.
Operating principle All objects, solid, liquid or gas, emit energy by radiation. The intensity of this energy depends on the temperature of the object. The JXB-178 infrared thermometer is therefore able to measure the temperature of a person by the energy the person emits. This measurement can be taken thanks to anexternal temperature probe on the device wh
Newest Added: RL37J526MSA/EG,INNOV-ISLTCS20040SDCP-8110DNYWED8300SW
Download User Manual